"Serving Northern California Since 1972"
Grass Valley (530) 273-0064 Yreka (530) 842-1111 Orangevale (916) 989-3000

PLUMBING EQUIPMENT

PORTABLE GAS METER

Where to find PORTABLE GAS METER in Chico

Image for reference only
Actual item may look different
Click on image for larger view

Manufacturer: RKI Instruments
Model: GX-2009
Daily: $55.00
Weekly: $210.00
Monthly: $630.00
Comments:
  • Gas Detected
  • Combustible Gases (Methane as standard)
  • Oxygen (O2)
  • Hydrogen Sulfide (H2S)
  • Carbon Monoxide (CO)
  • Detection Principle
  • Catalytic combustion
  • Galvanic cell
  • Electrochemical cell
  • Detection Range (Increments) 0 ~ 100% LEL (1% LEL) 0 ~ 40.0% Vol.
  • (0.1% Vol.) 0 ~ 100.0 ppm (0.5 ppm) 0 ~ 500 ppm (1 ppm)
  • Accuracy Statement 5% of reading or 2% LEL (whichever is greater) 0.5% O2 5% of reading or 2 ppm H2S (whichever is greater) 5% of reading or 5 ppm CO
  • (whichever is greater)
  • Sampling Method Diffusion sampling standard / hand aspirator or motorized pump optional
  • Display Digital LCD displays all four gases simultaneously, with auto backlight
  • Preset Alarms
  • (User Adjustable)
  • Overscale alarm
  • (Non-adjustable) 1st alarm 10% LEL
  • 2nd alarm 50% LEL
  • Over alarm 100% LEL Low alarm 19.5%
  • High alarm 23.5%
  • Over alarm 40.0% 1st alarm 5 ppm
  • 2nd alarm 30 ppm
  • TWA alarm 1 ppm
  • STEL alarm 5 ppm
  • Over alarm 100 ppm 1st alarm 25 ppm
  • 2nd alarm 50 ppm
  • TWA alarm 25 ppm
  • STEL alarm 200 ppm
  • Over alarm 500 ppm
  • Types of Alarms Gas Alarm: 2 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.
  • Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error
  • Display of Alarm Gas Alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), flashing gas value, vibration
  • Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message
  • Operating Temp. & Humidity -4 F to 122 F (-20 C ~ +50 C), 0 to 95% RH, non-condensing (splash resistant)
  • Response Time Within 30 seconds (T90)
  • Continuous Operation 20 hours after a 3 hour full charge (14 hours after 90 min charge)
  • Power Source Direct charging NiMH batteries, set of 2
  • Safety Design / Approvals IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; (optional MSHA version also available)
  • c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
  • Dimension & Weight 2.7 H x 3 W x 1 D (Approx. 70 H x 75 W x 25 D mm), 4.6 ounces (approx. 130 g)
  • Case Material High impact over molded rubber. Dust and water resistant with IP-67 approval.
  • Controls Two buttons: POWER / MODE, AIR
  • Datalogging Standard with all instruments. Stores 8 alarm trend sessions where readings are recorded 30 minutes
  • before and after an alarm event. 3,600 data point capacity with a log time range of 10 to 300 hours
  • (based on programmable interval times); and stores up to 100 calibration records.
  • Required Accessories Battery charger
  • Standard Accessories Alligator clip 13-0116RK
  • NiMH batteries (set of 2) 49-1609RK
  • Charging station with 115/220 VAC power supply (also available without power supply, 49-2170RK) 49-2170RK-01
  • Product CD (includes datalogging software) 71-8002RK
Add of the above items to my quote request
for a period of   day(s)   week(s)   month(s)  





* Please call us with any questions about our portable gas meter rentals serving Chico, Herlong, Sierra Army Depot, Susanville, Redding, Eureka, Red Bluff, Paradise California.